Overview
- Installation FlexibilityLong distanceLow temperature with defogging function4 safety areas controlled with one unitDouble muting SENSORS:
- Emitter-receiver photocells with test input
- Type 2 and Type 4 models
- Plastic tubular and MAXI formats
- Up to 50m operating distance
- Class 1 red laser emission models up to 40
- Standard M12 connectors
- Integrated control of 4 single beams and 2 light curtains
- Simple DIP Swicth configuration
- Muting functions can be assigned to light curtains or single beams
CONTROL UNITS:
Technical Features
Detection properties
| Nominal sensing distance | 60m |
| Sensitivity adjustment | Trimmer |
Application
| Function Principle | Through beam receiver |
| Description | Tubular M18 – axial optic |
| Functions | Through beam receiver |
Outputs
| Output type | PNP Don |
| Output Function | Don |
| Switching frequency | 1kHz |
| Response time | 0,33 |
Electrical data
| Operating Voltage | 10…30VDC |
| Load current | ≤100mA |
| Short-circuit protection | YES |
| Reverse Polarity Protection | Yes |
| Emission | n/a |
| Interference to external light | according to EN 60947-5-2 : 2020 |
| Impulsive Overvoltage Protection | Yes |
| Insulation resistance | >20 MΩ 500 Vdc, between electronics and housing |
| Contact resistance | 500 Vac 1 min., between electronics and housing |
Mechanical data
| Dimensions | Ø18×66 |
| Material | |
| Housing material | Plastic ABS / PMMA |
| Connections | M12 plug |
| Active Head Material | PMMA |
| Diameter/Dimension | M18 |
Test/Approvals
| Approvals | CE cULus |
| Shocks and vibrations | 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) |
Generical Data
| Dimensions | M18 x 1/L=66mm |
| Operating Temperature | – 10°C…+ 55°C |
| Mechanical Protection | IP67 |