Technical Data
Nominal size 100, 130 mm
Temperature ranges -70 … 600 °C / -100 … 1100 °F
Accuracy According to EN 13190
up to 250 °C: class 1
above 250 °C: class 2 (class 1 on request)
Protection rating IP 68 (EN 60529)
Immersion tube Stainless steel 1.4571 (AISI 316Ti)
Case Stainless steel 1.4301 (AISI 304)
Bezel ring Stainless steel 1.4301 (AISI 304)
Window Instrument glass
Window gasket Elastomer (silicone)
Dial Aluminium, white
Pointer Aluminium, black, adjustable
Minimum immersion
length
Immersion tube Ø 6 mm: L2 ≥ 65 mm
Immersion tube Ø 8 mm: L2 ≥ 50 mm
Temperature limit ranges ≤ 400 °C: 135 % F.S.
ranges > 400 °C: 100 % F.S.
ATEX Ex II2GDc
(with option 0078)
Vibrations According to IEC 60068-2-6:
10-58 Hz: 0.15 mm amplitude
58-150 Hz: 2g
According to MIL STD 810E, Meth. 514.4
10 Hz: 0.015 g2/Hz
40 Hz: 0.015 g2/Hz
500 Hz: 0.00015 g2/Hz